Doctors worldwide operate, diagnose and treat patients with the aid of med­

ical lights from Dr. Mach. For a very good reason: No other company offers a

detailed portfolio of this kind under one roof. No other company has such a

wealth of experience in the production and application of medical lights. And

no other company offers such quality and reliability. Dr. Mach was founded

75 years ago and today is still what it always has been: A specialised fami­

ly business with unique know-how. With ultramodern machinery and a well-

trained and skilled workforce from various specialist fields, we develop and

manufacture at our headquarters on the outskirts of Munich. All of our lights

are designed and produced in Germany and dispatched from our headquar­

ters. This, along with our endeavours to put the best lights at the disposal of

doctors, is undoubtedly the reason why our lights are amongst the best in the

world and are to be found in operating theatres in Montreal, Berlin or Kuala

Lumpur – and right across the world, to be concise.

-32

degrees is the average

temperature in winter at a

research station in Antarctica

where Dr. Mach OT-lights

have been working reliably

for years.

Quality in numbers

Quality can be expressed in numbers and dates. In 75 years we have created

and accomplished a huge amount. We have held hundreds of thousands of

talks and equally as many consultations. We have had tens of thousands of

meetings in which customer wishes and product improvements were con­

sidered. And we have equipped ten thousand doctors, practices and hospitals

with modern lights – on all of the earth’s continents, including Antarctica.

25

steps is the distance from

the CEO’s office to the

production hall.

154,000

lux is the difference be­

tween our first light and our

latest OT-light, the Mach

LED 8MC – an increase from

6,000 to 160,000 lux.

14,560

days is the lifespan of the

longest currently still in

use medical light from

Dr. Mach – in short:

it has been in use for 40

years.

139

constructional components

are needed to assembly our

Mach LED 8MC surgical light

in 25 precise work steps.

metres distant from the

earth flies the highest

Dr. Mach product in service:

a monitor holder that works

faultlessly even in the zero

gravity of outer space.

408,000

Ergänzungsprogramm

Kamerasysteme

It’s a matter of concentration, experience, perfection and millimetres.

It’s all about 100% reliance and not wasting any of one’s attention. It’s

about being able to accurately recognise tissue, structures and colour.

It’s about having the perfect light during the operation. For the light is

good only if it is ideal without the surgeon constantly needing to make

adjustments. Medical lights from Dr. Mach are therefore optimally

matched to the situation and needs during an operation. Easy to

handle, perfect in function, absolutely reliable and long-lasting.

As a result, OT-lights from Dr. Mach ensure that surgeons

worldwide are able to concentrate on what matters:

preserving health and saving lives.

“Besides the

illumination, I appreciate

features such as

shadow management,

extraordinary depth

illumination and un­

complicated handling.

They allow me to con­

centrate on what I am

best at: operate.”

Prof. Dr. med. Joachim Müller

ENT surgeon

Cascade system:

Various lens types create vertical focusing of the light

depth. This means: With increasing depth of the operating

field, the light no longer needs to be re-adjusted manually.

Shadow management:

Should the movements of the surgeon

block the light and thereby create shad­

ows in the wound area, this is compen­

sated immediately by an increase in the

light emission of other LEDs – hence

there are no shadows. As a result, the

light field is always thoroughly illumi­

nated during all movements.

Video management:

An HD or 4K camera which may optionally be

integrated enables operations to be filmed.

Thanks to high depth definition and autofocus,

razor-sharp images are always possible – ideal

for training purposes and documentation.

10

OT-lights Mach LED 6MC and LED 8MC

Shadow management

Laser pointer

Communication

Mechanical adjustment (larger light field diameter)

Wall-mounted control

Individual calibration of the colour temperatures

and light intensities

Diverse optional external interfaces and

connections (e.g. Storz, Bender etc.)

Camera preparation for HD or 4K camera (for details, please refer to

our separate documentation)

Options

Mach LED 8MC

Mach LED 6MC

Mach LED 150MC P

Can also be combined with

Light intensity at 1 metre distance

160,000 Lux

Colour temperature

3,750 – 4,750 Kelvin

Colour rendering index Ra

98

Colour rendering index R9

99

Light field diameter

19 – 30 cm

Diameter of the lamp head

66 cm

Number of LEDs on the lamp head

99

Lifespan of the LEDs

60,000 h

Light intensity at 1 metre distance

140,000 Lux

Colour temperature

3,750 – 4,750 Kelvin

Colour rendering index Ra

98

Colour rendering index R9

99

Light field diameter

18 – 30 cm

Diameter of the lamp head

58 cm

Number of LEDs on the lamp head

69

Lifespan of the LEDs

60,000 h

* Only 4,250 Kelvin for LED 6MC (BASIC)

Light intensity at 1 metre distance

130,000 Lux

Colour temperature

3,750 – 4,750 Kelvin

Colour rendering index Ra

97

Colour rendering index R9

93

Light field diameter

21 cm

Diameter of the lamp head

40 cm

Number of LEDs on the lamp head

26

Lifespan of the LEDs

60,000 h

11

Design

Aesthetics meets ergonomics meets high tech. Our OT-

lights are designed to be optimally functional, handled with

maximum convenience and radiate minimal heat.

Handle

By virtue of its asymmetric position, the Dr. Mach handle

allows the wound field to be illuminated optimally. In

addition, beside the focusing a second setting can be

controlled with the sterile area of the handle.

Laser pointer

An optional fine laser dot defines the centre of the light field

and thereby aids optimal alignment of the light field to the

wound area.

12

Highlights of the Mach LED 6MC

and the LED 8MC

Ceiling suspension OT-lights combi­

nation: 2-arm suspension for various

Dr. Mach light models. One arm with­

out stops 360° swivellable, other arm

swivellable with stop at 330°.

Mach LED 6MC and LED 6MC

on the standard axis

Outstanding depth illumination

One of the highlights of the new Mach LED 6MC and Mach LED 8MC is the cascade

system. Different lens types are used in this system. These lenses have their focus­

ing at 70, 100 and 130 cm. As a result, a vertical focusing of the light beam through­

out the depth of the wound canal can be achieved. Thus the surgeon no longer needs

to manually re-adjust the light when the depth of the operating field increases.

Large focusing range

The size of the light field can be varied by turning the sterilisable handle. The

focusable light beam allows spot illumination of deepest wound channels with high

light intensity and exact matching of the light field diameter to the surgical situation.

The focusing is achieved by means of mechanical (optional) and electronic light field

adjustment. The brightness of the light field remains constant.

Automatic shadow management

A further innovation is the shadow management, which is rendered possible by nu­

merous sensors in the light. Any cluster that has its light disturbed by the surgeon is

turned off. At the same time, the other light clusters increase in intensity in order

to compensate for the shadow. Even if the surgeon changes position, the light field

remains evenly illuminated without the need to move the light manually. The lux

remain constant.

13

Ceiling suspension OT-lights

combination: 2-arm suspension

for different Dr. Mach light models.

Both arms without stops 360°

swivellable. Also available as treble

and quadruple axis.

Mach LED 8MC and LED 6MC

on the heavy central axis

The diverse features of the LED 6MC and LED 8MC puts them amongst the most

modern OT-lights on the market. Every characteristic and functionality is aimed

at giving surgeons worldwide the best possible prerequisites for a successful

operation.

Almost perfect colour rendition

With almost perfect colour rendition values of Ra = 98 and R9 (red) = 99, you can

easily discern the finest colour nuances in tissue. To also recognise the different

red tones of the wound area, an exact rendition of the red colour range is essential.

Rendering index R9 (red) = 99 means the surgeon recognises details much more

easily. The colour spectrum of the wound area appears natural with rich contrast.

The OT-light is also noticeably more comfortable for the eyes.The colour spectrum

of the wound area appears natural with rich contrast. The OT-light is also noticeably

more comfortable for the eyes.

Antibacterial coating

For maximum hygiene in the operating theatre, the new generation of surgical lights

have a closed, easy-to-clean surface. In addition, they have an antimicrobial coating

that prevents the growth of microorganisms and thus helps to avoid infections.

Optimal flow properties

The shapes of the housings are aerodynamic and thus ideally suitable for

laminar-flow systems (climatic ceilings).

14

Suspensions and

configurations

Our OT-lights afford various combination- and suspension options.

Different methods of fixation and support arms are available. Here are some examples

of possible combinations. As a single light, the Mach LED 6MC is available as wall,

­ceiling and mobile model, the Mach LED 8MC only as ceiling model.

Single light with ceiling

­suspension

2 Mach LED 6MC and LED 150MC P

with storage tray on heavy central axis

5 Mach LED 6MC

with central spring arm

4 Mach LED 6MC

Wall model

3 Mach LED 6MC

Ceiling model

Light with only one quarter yoke,

recommended for a ceiling height

under 2.80 m

Triple combination with 4K camera

and storage tray

Single light on wall mount

1 Mach LED 8MC and LED 6MC

with tandem monitor carrier on heavy

central axis

Triple combination with 4K camera

and dual monitor carrier

15

16

Operationsleuchte Mach LED 300

Monitorträger I Ablagetisch I Kamerahalter

Mach LED 300DF SC

Light intensity at 1 metre distance

160,000 Lux

Colour temperature

4,500 Kelvin

Colour rendering index Ra

96

Colour rendering index R9

96

Light field diameter

17 – 25 cm

Diameter of the lamp head

55 cm

Number of LEDs on the lamp head

37

Lifespan of the LEDs

60,000 h

Light intensity at 1 metre distance

160,000 Lux

Colour temperature

3,750, 4,000, 4,250,

4,500, 4,750 Kelvin

Colour rendering index Ra

97

Colour rendering index R9

97

Light field diameter

18 – 26 cm

Diameter of the lamp head

55 cm

Number of LEDs on the lamp head

36

Lifespan of the LEDs

60,000 h

Light intensity at 1 metre distance

160,000 Lux

Colour temperature

4,500 Kelvin

Colour rendering index Ra

96

Colour rendering index R9

96

Light field diameter

19 – 26 cm

Diameter of the lamp head

55 cm

Number of LEDs on the lamp head

36

Lifespan of the LEDs

60,000 h

Mach LED 300DF SC Spot

OT-lights Mach LED 300

Mach LED 300MC

Central spotlight for improved depth illumination

Integrated HD camera (also can be retrofitted)

Wireless remote control

Please refer to our separate documentation for details of the

optional HD camera

Can also be combined with the OT-light LED 150MC P, for

technical details see page 10.

Options

17

Design

Aesthetics meets ergonomics

meets high tech. Our OT-lights are

designed to be optimally functional,

handle with maximum convenience

and radiate minimal heat.

Handle

By virtue of its asymmetric position,

the Dr. Mach handle allows the

wound field to be illuminated

optimally. Rotating the handle

focuses the light field. It’s sterile

area can also be used to adjust the

light field diameter mechanically

(LED 300 DF SC) or the colour

temperature (LED 300 MC).

Video

All of the LED 300 series lights

come with camera preparation

as standard (except the central

spotlight option). Thus an HD

camera can be retrofitted at any

time.

18

Excellent colour rendition

With excellent colour rendition values of Ra = 97 and R9 (red) = 97, you can easily

discern the finest colour nuances in tissue. To also recognise the different red tones

of the wound area, an exact rendition of the red colour range is essential. Rendering

index R9 (red)=97 means the surgeon recognises details much more easily. The colour

spectrum of the wound field appears natural and contrast-rich. The OT-light is also

noticeably more comfortable for the eye.

Facetted multi-lens system

A multitude of computer-calculated faceted lenses guarantees homogeneity and

lowest shadiness in the light field. Separately arranged optical systems, each with one

LED module, generate their own light field and thereby intensify the contrast effect of

the OT-light.

Merging of light fields

When the sterilisable handle is turned, the three LED clusters each containing 12

lenses swivel. The separate light fields can be bundled, depending on the working

distance, and merged into a single light field.

Focusing

The size of the separate LED clusters can be varied by turning the adjusting ring

on the sterilisable handle (LED 300DF SC). This allows spot illumination of deepest

wound channels with high light intensity and exact matching of the light field diame­

ter to the surgical situation.

Highlights of the Mach LED 300

Ceiling suspension OT-lights combi­

nation: 2-arm suspension for differ­

ent Dr. Mach light models. Both arms

without stops 360° swivellable. Also

available as treble and quadruple

axis.

Mach LED 300DF SC with spotlight

and Mach LED 300DF SC with camera

preparation on heavy central axis

19

Cool light

The use of LED modules reduces the radiated heat to a minimum. There is no

build-up of heat under The OT light. The area around the surgeon’s head remains

cool.

Aerodynamic design

The shapes of the housings are aerodynamic and thus ideally suitable for laminar-

flow systems (climatic ceilings).

Easy maintenance

With just a few steps the light housing can be opened to gain access to all of the sys­

tem components. Due to their modularity all components can be easily exchanged.

The housings are easy to clean.

Photobiological safety

The requirements of the photobiological safety standard DIN EN 62471 are met and

so there is no risk for the human eye even during very long and intensive use of the

OT-light.

Ceiling suspension OT-lights combi­

nation: 2-arm suspension for differ­

ent Dr. Mach light models. One arm

without stops 360° swivellable, other

arm swivellable with stop at 330°.

Mach LED 300MC with camera

preparation and Mach LED 300MC

with integrated HD camera on

standard axis

The OT-light LED 300 is one of the most popular on the market thanks to its ease

of operation and high functionality. With its mature, well-engineered design and

various options, it offers doctors and surgeons worldwide the reliable prerequi­

sites for a successful operative treatment.

20

3 Mach LED 300SC

Ceiling model

1 Mach LED 300DF SC with Spot

and LED 150FP

on the standard axis

2 Mach LED 300MC and LED 150MC P

on heavy central axis

5 Mach LED 300MC

with monitor carried on standard axis

4 Mach LED 300SC

Stand model

Suspensions and

configurations

Our OT-lights afford various combination- and suspension options. Different methods

of fixation and support arms allow attachment to almost all ceiling heights and carrier

systems. Here are some examples of possible combinations. As a single light, the

Mach LED 300 is available as wall, ceiling and mobile model.

Dual combination

Dual combination with central spring arm

Single light with ceiling suspension

Single light on four feet stand

Dual combination with monitor carrier

21